vmError: Warning, the Safe Path is not accessible (does not exist or no permission). For safety reasons it is very important to create a folder in a path not accessible by an URL or unguessable name, create also a folder 'invoices' and 'keys' in it to store your sensitive data secure. Our suggested path is for your system '/home/masmecdb/vmfiles/'.
You can also use complex folder name as 'password' for example '/home/masmecdb/public_html/administrator/components/com_virtuemart/mnyvqb5pC3iu/'. Use this link to the config

Print

Anaesthesia Machine -MAS6100A


Description

The Anesthesia machine makes a good performance in Intensive Care Units (ICU), Operation room, Anesthesiology Department and other departments. From high to low acuity, simple to complex cases, pediatric to geriatric patients, Superstar Medical Anesthesia Systems offer you the choices you need in ventilation, monitoring and technique. what’s more, our expertise in anesthesia delivery and ventilation is based on rich 23-year history of developing anesthesia solutions that meet your needs. Good performance based on High Security, High Accuracy, High Stability and accurate monitoring.

Trust Points

l Simplicity: easy to use, easy to move with 4 wheels.

l Choice: adapt the equipment to your patients and procedures freely

l Patient Centered Ventilation: Precision in an anesthesia ventilator, from conventional ventilation to advanced modes, including 3 modes: IPPV; A/C; SIMV.

l Designed and manufactured by Superstar Medical with over 23 years experience in this area.

l Flexible configurations to suit your needs.

l International standard and advanced technology suitable for wide range use.

l Compact interface and big screen give you better operating experience.

l Over 3,500 units installed in the world.

 

Features

l 10.4” TFT LCD touch screen displays the Ventilation parameters, Alarming information and Waveform.

l High precision flow meter, instantly know the fresh gas flow to your patient.

l Integration breathing circuit design, ensure easy operating and keep tidy.

l Multiple working modes such as volume control and pressure limit, adapt to wide range patient.

l Vaporizer with temperature, flow compensation and self-lock function, keep safety anytime.

l Multiple parameters monitoring interface, make every parameter clear, let users know the patient conditions in all aspects;

l Real time pressure-time, flow-time loop graphics and high precision O2 concentration detection function included.

l Vital sign monitor and Anesthetic gas monitor are optional.

 

Safety

l Three level alarming system, visual and sound alarm information.

l With lots of alarming, reminding and protection functions.

l Advanced power management control technology.

l With built-in backup power source, when outside power source goes off, back-up power source starts to work.

l Low O2 pressure alarm and N2O cut-off protection.

 

Specifications


Ventilation modes:

 

IPPV; A/C; SIMV
Ventilator parameter ranges  
Flow meter O2(0.1-10L/min)
  N2O(0.1-10L/min)
  AIR(0.1-10L/min)
Rapid oxygen supply 25L/min-75L/min
Tidal volume(Vt) 0, 20 mL ~ 1500 mL
Frequence(Freq) 1bpm ~ 100 bpm
I/E 2:1~1:6
PEEP 0cmH2O ~ 30 cmH2O
Pressure triggering sensitivity(PTr) -20 cmH2O ~ 0 cmH2O(Based on PEEP)
Flow trigger sensitivity (FTr) 0.5 L/min ~ 30 L/min
SIGH 0(off)  1/100 ~ 5/100
Apnea Ventilation OFF,5 s ~ 60 s

Pressure Limit

 

20 cmH2O ~ 100 cmH2O
Monitored Parameters  
Frequence(Freq) 0 /min ~ 100 /min
Tidal volume(Vt) 0 mL ~ 2000 mL
MV 0 L/min ~ 100 L/min
Oxygen concentration

15 % ~ 100 %

 

Graphical display:  
P-T(pressure – time)  
F-T(flow – time)  

 

Size

Wooden case packing size:L 845*W 900*H 1525mm , GW:151KG ; NW:102KG

 

Alarm and protection

The AC power failure alarm Power failure or no connection
Internal battery backup low voltage alarm <11.3±0.3V
No tidal volume ≤5Ml within 6s

High oxygen concentration alarm

Low oxygen concentration alarm

19%-100%

18%-99%

High Airway  pressure alarm

Low Airway  pressure alarm

High Minute Volume alarm

Low Minute Volume alarm

Continuous Pressure alarm

20cmH2O-100cmH2O

0cmH2O-20cmH2O

Adult(5L/min-20L/min) Paed(1L/min-15L/min

0-10L/min)

(PEEP+1.5kPa) over 16s

Suffocation warning 5s-60s no spontaneous ventilation
The maximum limited pressure <12.5 kPa

Fan error

Oxygen deficit

 

Show on screen

Show on screen

Working conditions  
Gas source O2,N2O,AIR
Pressure</