vmError: Warning, the Safe Path is not accessible (does not exist or no permission). For safety reasons it is very important to create a folder in a path not accessible by an URL or unguessable name, create also a folder 'invoices' and 'keys' in it to store your sensitive data secure. Our suggested path is for your system '/home/masmecdb/vmfiles/'.
You can also use complex folder name as 'password' for example '/home/masmecdb/public_html/administrator/components/com_virtuemart/cUIM6aXFhzwC/'. Use this link to the config

Print

High Frequency X-ray Radiograph System


Description

Dimensions:

Machine:225*118*100cm GW:770kg NW:550kg

Control console:120*115*143cm GW:380 kg NW:300kg

Bucky stand: 208cm*73cm*87cm GW:235kg NW:189kg

Specification:

Item

content

Output power

55kW

Main inverter frequency

60kHz

X-ray tube

(SIEMENS RAY®-14_1)

Rotary anode, dual-focus, large focus: 1.2mm, small focus: 0.6mm, the frequency for large is 78kW and small is 33kW.

Anode thermal capacity:260kJ (370kHu)

Tube thermal capacity: 1000kJ (1780kHu)

Rotary anode speed

8500rpm-10800rpm

mA range

10mA-500mA

Tube voltage

40kV-140kV

Anode target surface angle

12°

mAs

0.1-630mAs

Table radiography grids

Grid density:103L/INCH;Grid ratio:10:1;Focusing distance:120cm;Stationary type:15"×18"

Exposure Time

0.001s-12.5s

Power supply

380/400VAC three phase, 50Hz.

Operation method

close-table graphic program controlled LCD touchable screen operation; wireless remote control exposure

Basic Configuration:

1, New integral radiography table (with pillar) one unit

2, Combined high-frequency high-voltage X-ray generator one set

3, Colored LCD touch screen control box one unit

4, Collimator one set

5, Electric box one unit

Structural Performance:

 

Table size

2000×760mm

Table height

≤700mm

Table transverse movement

≥220mm

Table longitudinal movement

≥900mm

Grids cassette holder movement

≥560mm

X-ray tube assembly center rotation

≥±120°

Rotation of the pillar

4×90°

Axial rotation

0-35°

SID

450-1200mm

Pillar movement along the table

≥1370mm

Film size in grids cassette

Max 356mmX432mm(14’’x17’’)

 

Hot Features:

  1. It is installed with close-table graphical colorful LCD touch screen and wireless remote control exposure, which makes the operator easy to use.
  2. We incorporate the latest compact high-frequency and high-voltage X-ray generator, which ensure superior image quality, while the skin dose is low, to protect the patient better.
  3. It can choose KV, MAS two buttons system, photograph mode and KV, MA, S three buttons system, two photography mode could meet different users professional requirements perfectly
  4. Adopt the technology of kV and mAs num

Reviews