vmError: Warning, the Safe Path is not accessible (does not exist or no permission). For safety reasons it is very important to create a folder in a path not accessible by an URL or unguessable name, create also a folder 'invoices' and 'keys' in it to store your sensitive data secure. Our suggested path is for your system '/home/masmecdb/vmfiles/'.
You can also use complex folder name as 'password' for example '/home/masmecdb/public_html/administrator/components/com_virtuemart/zYdbkPZMJyeq/'. Use this link to the config

Print

Transport incubator BT-100

This is a lightweight, flexible incubator. It is suitable for all ambulances.

Description

Transport incubator BT-100 main function

Brief introduction:

Air mode and Baby mode controlled by micro-computer;

Use AC Power and DC Power alternatively, DC 12V or DC 24V Power on the ambulance;

Set temperature, air temperature, baby temperature and internal battery voltage can be displayed separately;

Failure alarm indication;

Double wall Acrylic glass hood with side door so that the bassinet can be pulled out from it;

Natural air flow humidity;

The height of whole unit can be adjusted;

With Oxygen cylinder and Oxygen supply configuration;

Observation lamp.

Standard Configuration:

Main body (including the hood,controller,bassinet,internal battery,and observation lamp),oxygen supply system,skin temperature sensor,I.V.Pole,mattress,adjustable stand)

Optional Configuration:>37°C override temperature mode

Specification:

AC Power supply:AC220V-230V/50HZ

DC Power supply:DC12V/10A or 24V/6A

Input Power:400VA

Mode of control: Air mode and Baby mode controlled by micro-computer

Air temperature control range:25°C-37°C

(Override mode):37-38°C

Baby temperature control range: 34°C-37°C

(Override mode):37-37.5°C

Skin temperature sensor accuracy: 0.3°C

Temperature variability : 1.0°C

Temperature uniformity : 1.5°C(mattress is on the horizontal position)

Noise inside hood : 55dB(A) (Environment noise 45Db(A) )

Failure alarm :over-temperature alarm, temperature diviation alarm,sensor alarm,motor fan failed alarm,power failure alarm and so on.

Operating at temperature equilibrium :90 min (Set Temp 36°C, Ambient 15°C)

Environmental temperature:

Operating range: 10°C-30°C

(Set temperature should be higher 3°C than the environment temperature)

Ambient air movement rate : 1.0m/s

Package:

Package : each unit is packed as two carton

Size(Main body): 109cm x 65.5cm x 76cm

(Cabinet): 138cm x 61cm x 40cm

Gross weight(Main body): 80kg

(Cabinet): 53kg